US Robotics COURIER Manual do Utilizador Página 146

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 308
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 145
U.S. Robotics I-modem Command Reference
Querying • Page 12-17
Disconnect Reasons for Dial Security
I7 Display the product conÞguration. If you have a problem and call U.S.
Robotics' Technical Support staff, you may be asked to read this screen.
Table 12-3. Dial Security Disconnect Reasons
Disconnect
Reason Explanation
Mode
Incompatible
The I-modem hung up because both devices were not set to the same error-con-
trol setting.
No Prompting
in Non-ARQ
Prompting was enabled, but the I-modem hung up because the originating
device was set for error control, and the answering device was set for non-error
control. The answering device cannot prompt when it is set for non-error control.
No Prompting
in Sync
(External
I-modems only)
The originating device did not send an Autopass password, and the answering
device cannot prompt for a password in any synchronous
mode.
Non-ARQ Mode The I-modem hung up because the originating device was set for error control
and the answering device was set for non-error control.
Prompting Not
Enabled
The I-modem hung up because the originating device did not send an Autopass
password, and prompting wasn't enabled.
Security Abort The I-modem hung up because it received an invalid password three times.
Vista de página 145
1 2 ... 141 142 143 144 145 146 147 148 149 150 151 ... 307 308

Comentários a estes Manuais

Sem comentários