20 Sun StorageTek SAM Archive Configuration and Administration Guide • Version 4, Update 6, 04/07
The Sun StorageTek SAM system moves the cartridge from the mailbox to a storage
slot and updates the library catalog. In addition, after this command is issued, the
cleaning media flag is set, and the access count is set to the appropriate number of
cleaning cycles, based on the media type. Each time the cartridge is used to clean a
drive, the access count is decremented.
▼ To Use a Cleaning Cartridge Without a Barcode
If the cartridge is not barcoded, you must import it first. It is not automatically
marked as a cleaning cartridge.
1. Use the import(1M) command to import the cartridge into the automated library.
For eq, specify the equipment ordinal of the automated library as defined in the mcf
file.
2. Use the chmed(1M) command to change the type to a cleaning cartridge.
For eq, specify the equipment ordinal of the automated library. For slot, specify the
slot in which the cleaning cartridge has been loaded.
In the following example, the automated library is equipment ordinal 50 and the
cleaning cartridge is in slot 77:
3. Use chmed(1M) again to set the cleaning cycle count.
For eq, specify the equipment ordinal of the automated library. For slot, specify the
slot in which the cleaning cartridge has been loaded.
The following example command sets the count on the cartridge used in the
preceding step:
import eq
chmed +C eq:slot
# chmed +C 50:77
chmed -count count-number eq:slot
# chmed –count 20 50:77